Clinical Features Explained

ECGEN-Eval can measure ten clinical features on every ECG: the same timings and heights a cardiologist looks at first. This section explains them for readers without a medical background, with interactive pictures instead of jargon.

Educational material, not medical advice

The heartbeats here are simplified drawings. The "typical" ranges are rough guides for resting adults; real cut-offs vary with age, sex, the lead and the guideline. Use them to understand synthetic ECGs, not to read anyone's medical ECG.

What an ECG is

Every heartbeat is started by a tiny electrical wave that travels through the heart muscle, a little like a stadium wave travelling around a crowd. Muscle squeezes when the wave reaches it. Electrodes on the skin pick up this wave, and the ECG draws it as a line over time:

  • Left to right is time. On standard ECG paper, 1 small box = 40 ms (0.04 s) and 1 big box (5 small boxes) = 0.2 s. Five big boxes are one second.
  • Up and down is voltage. 1 small box = 0.1 mV, so 10 small boxes = 1 mV.
  • Flat means nothing is changing, not that the heart is "off".

Each heartbeat leaves the same pattern of bumps, named with letters: P, Q, R, S, T. The features below are the widths, gaps and heights of those bumps, and the time between beats.

Anatomy of one heartbeat

Press Play to watch the electrical wave travel through the heart while the ECG is drawn. You can also click any part of the trace or use the buttons. The heart on the right shows which part of the heart is active at that moment.

Interactive heartbeat loading… (needs JavaScript)

In short:

ECG part What the heart is doing Plain-language picture
P wave Upper chambers (atria) are activated The "starter" squeeze that tops up the lower chambers
PR segment Signal waits at the AV node A gate that pauses the signal so the lower chambers can fill
QRS complex Lower chambers (ventricles) are activated The main pump stroke; the biggest spike
ST segment Ventricles fully activated A quiet moment, should be on the baseline
T wave Ventricles recharge Resetting, ready for the next beat
Rest Heart relaxes and refills The pause before the next beat

The features

  • Heart rate & RR interval


    How fast the heart beats, and the time from one beat to the next.

    hr_bpm · rr_mean_ms · rr_std_ms

  • P-wave duration


    How long the upper chambers take to activate.

    p_wave_duration_ms

  • PR interval


    How long the signal takes to get from the upper to the lower chambers.

    pr_interval_ms

  • QRS duration


    How quickly the electrical wave spreads through the lower chambers.

    qrs_duration_ms

  • QT interval & QTc


    How long the lower chambers take to activate and recharge, corrected for heart rate.

    qt_interval_ms · qtc_bazett_ms

  • ST deviation


    Whether the quiet stretch after the main spike sits on the baseline.

    st_deviation_mv

  • T-wave amplitude


    How tall the recharge bump is, and whether it points up.

    t_amplitude_mv

  • Heart-rate variability


    How much the time between beats changes from beat to beat.

    hrv_sdnn_ms · hrv_rmssd_ms · hrv_pnn50

Feature Column Unit Typical resting adult (rough guide)
Heart rate hr_bpm beats per minute 60–100 bpm
RR interval rr_mean_ms, rr_std_ms ms 600–1000 ms
P-wave duration p_wave_duration_ms ms up to 120 ms
PR interval pr_interval_ms ms 120–200 ms
QRS duration qrs_duration_ms ms under 110–120 ms
QT interval qt_interval_ms ms depends on heart rate
QTc (Bazett) qtc_bazett_ms ms about 350–450 ms
ST deviation st_deviation_mv mV close to 0
T-wave amplitude t_amplitude_mv mV positive in most leads
HRV hrv_sdnn_ms, hrv_rmssd_ms, hrv_pnn50 ms, ms, % depends strongly on age and recording length

Why they matter for synthetic ECGs

A generator can learn to draw something that looks like an ECG at a glance but breaks the rules of how a heart works: a P wave glued to the QRS, a QRS twice as wide as any real one, a T wave that never ends. Signal-level metrics such as MMD or FED may miss this. A cardiologist would spot it in seconds.

Clinical features check exactly these rules. The question is not "is every value normal?" (real datasets contain disease), but "do the synthetic features follow the same distribution as the real ones?" If 10 % of real ECGs have a wide QRS, about 10 % of synthetic ones should too.

Use it with ECGEN-Eval

pip install "ecgen-eval[features]"   # adds NeuroKit2 for wave delineation

# One CSV row per recording, with a `dataset` column
ecgen-eval features --real real.npy --synthetic synth.npy --fs 500 --output features.csv

# Or add 2-D / 3-D feature plots to the HTML report
ecgen-eval eval --real real.npy --synthetic synth.npy --feature-plots --output report.html
from ecgen_eval import load_ecg_npy
from ecgen_eval.features import extract_features

real = load_ecg_npy("real.npy", fs=500)
synth = load_ecg_npy("synth.npy", fs=500)

_, real_summary = extract_features(real)    # one row per recording
_, synth_summary = extract_features(synth)

cols = ["hr_bpm", "pr_interval_ms", "qrs_duration_ms", "qtc_bazett_ms"]
print(real_summary[cols].describe().round(1))
print(synth_summary[cols].describe().round(1))

Beats are found on one lead (lead II by default, see lead_for_intervals); the wave boundaries use all leads, and the ST and T heights are measured on every lead and averaged. The Clinical Features user guide covers the options and output tables. The ECG Feature Review gives the clinical background and references.

How well the measurements agree with clinical software

The extractor was compared with the GE 12SL measurements that PTB-XL+ publishes for every PTB-XL recording. The check used 500 recordings from PTB-XL fold 9 (12 leads, 500 Hz, 10 s), which were not used to tune the extractor. For context, the last column shows how well two commercial programs, GE 12SL and Philips Uni-G, agree with each other on the same kind of data. P-wave boundaries are hard to pin down even for them.

Feature Ours vs 12SL: mean difference typical error (MAE) correlation r 12SL vs Uni-G (r)
hr_bpm −0.4 bpm 1.7 bpm 0.90 —
pr_interval_ms +2 ms 8.5 ms 0.87 0.89
qrs_duration_ms +1 ms 6.4 ms 0.88 0.88
qt_interval_ms −17 ms 22.6 ms 0.85 0.96
qtc_bazett_ms −17 ms 25.5 ms 0.63 0.81
p_wave_duration_ms −4 ms 12.0 ms 0.41 0.48
t_amplitude_mv (lead average) +0.01 mV 0.96
st_deviation_mv (lead average, vs Uni-G at J + 80 ms) 0.00 mV 0.97

How to read it:

  • Heart rate, PR, QRS, T amplitude and ST match the clinical software about as closely as the two commercial programs match each other.
  • QT follows 12SL closely (r 0.85) but is about 17 ms shorter on average: the tangent method used for the end of the T wave is known to end it earlier. QTc inherits this, and it also adds the small errors of QT and RR together, so its correlation is lower.
  • P-wave duration is the least reliable feature for every algorithm, including the commercial ones.
  • Accuracy drops with fewer leads (single-lead QRS r ≈ 0.5) and lower sampling rates (at 100 Hz, PR r 0.93 but QRS MAE 13 ms and QT r 0.73).
  • Without NeuroKit2, heart rate, HRV, QRS duration, ST and T amplitude are still measured; PR, QT, QTc and P-wave duration are NaN.

Because real and synthetic data go through exactly the same extractor, small systematic offsets such as the QT bias cancel out when you compare their distributions.

Changed in v0.7.0

In v0.6.0 and earlier, PR, QT, QTc, P-wave duration and ST deviation were always NaN with NeuroKit2 installed (and fixed placeholder values without it), and QRS was measured from the Q dip to the S dip. Re-extract features made with those versions before comparing them with new results.